ContractBeam
The Registry

Browse opportunities

softwareSet-aside: No Set aside usedclear all
ContractNo Set aside used1 day left

Supply Chain Threat Intelligence & Remediation Software Platform

This is a Notice of Proposed Contract Action under RFO Part 12 Acquisition of Commercial Products and Commercial Services. This notice is for information only; a solicitation will not be issued. THIS IS NOT A REQUEST FOR QUOTATION. No contract will be awarded on the basis of offers received in response to this notice. The associated North American Industry Classification System (NAICS) code is 513210 (Software Publishers) with a small business size standard of $47,000,000 in average annual revenue. The Government requires procurement of a Supply Chain Threat Intelligence & Remediation software platform that will be capable of ingesting Software Bills of Materials (SBOMs) and performing deep dependency analysis for any software application type. This software tool will provide the Government with a threat intelligence platform and software supply chain threat remediation capability. The license structure will include a base year and 1 option year. The Government intends to negotiate a sole-source contract for this requirement with Unison Solutions, Inc. 4235 Tejon St, Denver, CO 80211. Sole distributor of the Warpstone Technologies Supply Chain Threat Intelligence & Remediation software platform. The Warpstone software tool is available from only one responsible source and no other type of supplies or services will satisfy agency requirements. Warpstone is the only company taking a wholistic look at software supply chain risk management without a container focus. Warpstone’s novel tracking system for vulnerabilities that will enable actionable insights which improve security posture and accelerate Zero Trust capabilities. Warpstone's product will expand capabilities from only being able to assess containers to more types of artifacts. Including software binaries, libraries, software components, and containers. Additionally, the tool is remediation focused, meaning that instead of making a static risk assessment, it allows the Government to manage risk throughout an entire enterprise. Further, Warpstone is the only known commercial platform offering a non-proprietary access code. This is a notice of proposed contract action and not a request for competitive quotes; however, all responsible sources may submit a capability statement or quote, which shall be considered by the agency. All inquiries should be sent by email to the POCs listed in this notice. Responses must be submitted by the date/time listed on the notice. Any response to this notice must show clear and convincing evidence that competition would be advantageous to the Government in future procurements. Responses received will be evaluated. However, a determination by the Government not to compete the proposed procurement based upon responses to this notice is solely within the discretion of the Government. The Government anticipates an award date on or before 31 August 2026.

AgencyDEPT OF DEFENSE
NAICS513210
PlaceRome, NY
SAM.gov· Posted Jul 18, 2026#FA875126QWARP
ContractNo Set aside used4 days left

LSM990 Confocal Airyscan2 System

This notice is to update FAR clauses and the attachment. There are no other changes to this notice. 1 GENERAL INFORMATION This is a combined synopsis/solicitation for commercial products prepared in accordance with the Far Part 12 as supplemented with additional information included in this notice, and in conjunction Far 8.402(f). This announcement constitutes the only solicitation; quotations are being requested, and a separate written solicitation will not be issued. The National Institutes of Health (NIH), National Institute on Deafness and Other Communication Disorders (NIDCD), Intends to contract on a sole source basis with Carl Zeiss Microscopy – One North Broadway, White Plains, NY 10601 to procure a LSM 990 w/Airyscan-2 Microscope consisting of all the items per the attachment provided in this notice. The Government intends to award a Firm-Fixed-Price Purchase Order resulting from this solicitation. 2. DESCRIPTION OF REQUIREMENT 2.1 Background The NIDCD relies on high-resolution microscopy to image mouse inner ear tissues and to perform live imaging of cellular organelle development and function in zebrafish. The LSM990, equipped with the proprietary Airyscan 2 detector, provides the spatial resolution and sensitivity required to visualize subcellular structures that cannot be adequately resolved with conventional confocal microscopy. The 32-channel GaAsP detector array achieves resolution of approximately 90 nm in the lateral dimension and 200 nm in the axial dimension while simultaneously improving signal collection efficiency. The enhanced sensitivity of the Airyscan 2 detector allows imaging at lower laser powers, reducing photobleaching and phototoxicity during long-term live imaging experiments. This combination of high resolution and gentle imaging is essential for studying dynamic cellular processes in living tissues. In addition, the LSM990 offers substantial improvements in data handling compared with the older LSM780, generating raw datasets that are approximately eight-fold smaller and enabling Airyscan image processing that is up to five-fold faster. These advances improve both experimental throughput and data management for high-resolution live imaging studies. The Zeiss LSM 990 with Airyscan 2 enables gentle, high-sensitivity imaging of both live and fixed samples, including fine structures in the mouse inner ear and zebrafish lateral line. The Airyscan 2 detector array improves signal detection and spatial resolution while allowing imaging at low laser power, thereby minimizing photobleaching and phototoxicity. The Labs’ current Zeiss LSM780 confocal system is heavily used by researchers from three NIDCD laboratories and is no longer covered by a service contract, with many replacement parts no longer available. Zeiss ZEN software is user-friendly and intuitive, allowing new users to become proficient quickly. Because the LSM990 operates on the latest version of the same software platform, it will provide a seamless transition while ensuring reliable, faster, higher-quality, and more efficient image acquisition for the many NIDCD investigators who depend on this system. Overall, the Zeiss LSM 990 will provide essential imaging capabilities and meet current and future microscopy needs at NIDCD. Brand Name Only: Sole Source Authority - 12.102(b) for Open Market and 8.405-6 for GSA items The Airyscan detector of LSM990 system represents a proprietary technology from Carl Zeiss Microscopy, LLC and a continuation of Airyscan detector use in the lab is essential to generate high-resolution publication quality data and efficiently complete the research projects that are ongoing in the lab using this detector, only Zeiss LSM990 system would suffice the goal. 3. DELIVERY / PLACE OF PERFORMANCE Delivery, installation, re-alignment and recalibration once the microscope systems have been added to its permanent location in the lab. National Institutes of Health 9000 Rockville Pike Building 35A, Room 1D-9…

AgencyHEALTH AND HUMAN SERVICES, DEPARTMENT OF
NAICS334516
PlaceBethesda, MD
SAM.gov· Posted Jul 29, 2026#75N98026Q00888