ContractBeam
ContractOpen solicitation — bid to win the workRolling / no deadline

4610--Continuous Water Monitoring System

Point of contact

Minnisha Hearst

Minnisha.Hearst@va.gov
Before you bid: ContractBeam aggregates public government data and may lag the official record. Always confirm the scope, deadline, and submission instructions on the official source below before acting.

Related open opportunities

Contract1 day left

Z2DA--542-23-201 | Replace Roofs Building 69 and 139 | NCO 4 Construction East (VA-26-00047303)

Replace Roofs Building 69 and 139 Project No. 542-23-201, Solicitation 36C24426B0010 Amendment No. 002 Additional Contractor Questions and VA responses (bold). Please provide a copy of the phase 1 asbestos survey/report (or any applicable hazardous materials report) covering the scope of work for this project. This can be found in the Design Narrative - Appendix D The taper drawing on sheet A-105 shows a Y-panel start at the roof drain with a starting thickness of 1½-inch (R-8.6). The taper drawing on sheet A-110 shows an X-panel start at the roof drain with a starting thickness of ½-inch (< R-3). This contradicts with Specification Section 07 22 00, paragraph 2.1.A.2 which requires an R-10 minimum (or 1¾-inch) at any location. Which taper should be provided, the ones shown in the plans, or that which is in the specifications? The tapered insulation layouts included in the drawings are provided to show intended slope of the finished roof. These do not include information about a base layer which will be required on each building to achieve the required R-values: minimum R-10 and overall average R-33 as required in the specification refer to section 072200 2.1 A.  Tapered insulation shop drawing submittal shall include evidence of calculated average R-value meeting this minimum requirement. Please provide a typical roof system detail for the shingle assembly similar to that shown on Detail 2/A-503 for the low-slope assembly. Where does the composite nail base specified in Section 07 22 00, paragraph 2.4.D get installed? Please specify the thickness required. This was taken from the VA.TIL specs we had left this in the specifications for the penthouse shingled roof.  VA requires adherence with the specification. For the skylight removal on Building 139, Details 2 & 3/S-104 appear to indicate that a new raised deck will be installed approximately 14-inches above the existing roof. This would create a base flashing condition. Sheet A-107 does not show this raised area. Will the new structural deck at the skylight removal be flush with the existing deck, or will it be raised? If raised, please provide details showing the roof flashing and termination conditions at this area. The design intent is for the roof deck infill to be placed on the existing curbs and be raised as shown in the detail on S104. This allows for the 6" cold form to be installed to support the new ceiling within these skylights. The flashing detail is similar to Detail 4 found on sheet A503. Section 07 31 13, paragraph 2.1.A refers to Section 09 06 00 for the shingle Basis of Design. The 09 06 00 specification states the shingle size, shape, and manufacturer are to be selected. Please provide a basis of design for the shingles. Refer to section 073113 2.2, for requirements. Will snow guards be required on the shingle roof? There are currently snow guards installed in the shingle roof only above the penthouse doorway but not the entire perimeter. VA requires to maintain snow guards in that location.  These are listed in 073113 2.7 Section 07 52 16.11, paragraph 2.3.C.2: are bio-based SBS modified bitumen products applicable to this project? Yes, cold applied membrane adhesives are required to have bio-based content. Refer to 075216 2.5 C and D Referring to Detail 3/A-503, the replacement fascia appears to be a unique custom prefabricated item. Please provide a manufacturer basis of design for this fascia. Include material type and size/thickness. Also, please provide attachment requirements and details. Match existing adjacent trim in materiality and method of connection. Referring to Detail 3/A-503, the shingles and roof felt appear to be installed over some sort of insulation and a wood starter block. Is this insulation currently in-place? What substrate will the shingles be nailed to? Nail base (refer to question 4). Note that this is not a vented product consider a vented nailboard (see Hunter Cool-vent as an example). Refer to the phasing pl…

AgencyVETERANS AFFAIRS, DEPARTMENT OF
NAICS236220 · Commercial & Institutional Building Construction
SAM.gov· Posted Jul 2, 2026#36C24426B0010
ContractNo Set aside used1 day left

Design-Bid-Build (DBB) SOF Marine Raider Facilities Complex, Marine Corps Base (MCB) Camp Lejeune, North Carolina

The general intent of this solicitation is to award a Fixed Price Construction Contract for a Design-Bid-Build (DBB), construction services for the P-1550 SOF Marine Raider Battalion Company & Team Facilities located at the Marine Corps Base in Camp Lejeune in North Carolina. The project is to provide construction of 6,815 SM (73,400 SF) SOF Marine Battalion Operations, Supply, Communications, and Intel facility; 11,812 SM (127,200 SF) Company HQ and Team Facilities; 1,635 SM (17,600 SF) Company Storage Buildings and miscellaneous supporting structures, utilities, parking, roadways, pedestrian ways/sidewalks, and site work at Stone Bay at the Marine Corps Base (MCB) in Camp Lejeune, North Carolina. The structures will be single-story steel frame buildings with brick veneer over metal studs, standing seam metal roofs, metal soffits, and translucent wall panels. Special construction features include pile foundations, surcharged sites, wetlands mitigation, and storm water best management practices.

AgencyDEPT OF DEFENSE
NAICS236220 · Commercial & Institutional Building Construction
PlaceCamp Lejeune, NC
SAM.gov· Posted Jun 29, 2026#N4008526R0138
Contract1 day left

Solicitation for Design-Build (DB), B-550 Repair MCIS/Student HSG Dam Neck Annex, Naval Air Station Oceana, Virginia Beach, VA

See all applicable attachments. Attachment E- B550 DB RFP_VOL 2 of 3 - ATTACHMENTS A-0 is too large to upload to SAM. Interested parties may contact Shayna Eichner at Shayna.T.Eichner.civ@us.navy.mil to request the attachment be sent via DOD SAFE. Please note: This solicitation and all applicable attachments are restricted to MACC holders (N4008521D0079-0086) under the INDEFINITE-DELIVERY/INDEFINITE QUANTITY (IDIQ) MULTIPLE AWARD CONSTRUCTION CONTRACT (MACC) FOR LARGE GENERAL CONSTRUCTION PROJECTS PRIMARILY IN THE HAMPTON ROADS AREA OF RESPONSIBILITY (HR AOR), VIRGINIA.

AgencyDEPT OF DEFENSE
NAICS236220 · Commercial & Institutional Building Construction
PlaceVirginia Beach, VA
SAM.gov· Posted Jun 16, 2026#N4008526R0099